Pune, India, 411001
Product Description The BMC H80M High Flow Oxygen Therapy Device is designed to deliver high-flow nasal oxygen therapy for patients with respiratory distress, hypoxemia, or post-operative needs. Its advanced flow and FiO₂ control ensures accurate oxygen delivery, while the heated humidification system prevents airway dryness and improves patient comfort. The device features an easy-to-use digital touchscreen, real-time monitoring, and adjustable alarm settings for safe and continuous therapy. Suitable for neonatal, pediatric, and adult patients, it is portable and lightweight for bedside, ICU, or emergency room applications. With proven performance in critical care settings, the BMC H80M HFNC helps reduce intubation rates, enhances oxygenation, and provides safe, reliable therapy for long-term oxygen support. ⭐ Specifications Device Type: HFNC (High Flow Nasal Cannula) Flow Rate: 5–80 L/min FiO₂ Range: 21–100% Heated Humidification: Adjustable 31–37°C Alarms: Flow, FiO₂, temperature, disconnection Display: Digital touchscreen Portable: Lightweight, bedside-friendly Power Supply: AC mains Safety: Over-temperature & over-pressure protection Patient Compatibility: Neonatal, pediatric, adult ⭐ Applications ICU & critical care Respiratory therapy for neonates, children, and adults Post-operative oxygen support Hypoxemia treatment Emergency room & step-down units ⭐ What’s in the Box BMC H80M HFNC device Heated humidifier chamber Nasal cannula sets Power cord User manual ⭐ FAQs Can it be used for neonates? Yes, fully adjustable for neonatal patients. Does it have heated humidification? Yes, prevents airway dryness. Is FiO₂ adjustable? Yes, 21–100%. Are there alarms for safety? Yes, multiple alarms for safe operation. Is it portable? Yes, lightweight and suitable for bedside use. ...Read Less More info HFNC_Oxy_ther_humdi 220500 H-80M Series High Flow Oxygen Cannula : Product description The H-80M Series High Flow Oxygen Cannula (HFNC) supports patients with spontaneous breathing—including cases of artificial airway respiratory insufficiency—across hospital and long-term care settings. It delivers up to 80 L/min air-oxygen mixed gas. Oxygen concentration can be set automatically and the device provides exclusive AutoFlow and SmartFlow functions for consistent therapy. A disinfection-free design simplifies upkeep, and the humidifier’s water chamber includes a backflow-prevention valve to avoid gas backflow. Key Features : Up to 80 L/min therapeutic high-flow delivery. Automatic oxygen concentration control with AutoFlow & SmartFlow. Disinfection-free design for easier maintenance. Water chamber with anti-backflow valve for added safety. Suitable for wards, ICUs, and long-term care institutions.